This guide is for the person who builds and installs PoolWind: installing the software, fitting it to your pool, and the settings behind the scenes. Swimmers only need the user manual.
Please read SAFETY.md first. Several steps here move the pool’s jet. Do them with nobody in the pool.
poolwindOpen a terminal on the Pi: click the Terminal icon (a black screen
with >_) on the bar at the top of the desktop. Type these four lines,
pressing Enter after each:
cd ~
git clone https://github.com/WillyAG/PoolWind.git PoolWind-download || git -C PoolWind-download pull
cd PoolWind-download
bash install.sh
Easier than typing: copy the lines from this guide on the Pi itself.
github.com/WillyAG/PoolWind in its address bar at the
top, and press Enter. The first time the browser opens, it may ask for
a password for a “Default keyring”: click Cancel. It won’t ask
again once PoolWind is installed.The first line goes to your home folder. The second downloads PoolWind
into a PoolWind-download folder there; if that folder is already there
from an earlier install, the download says “fatal: … already exists”
(that’s fine) and the folder is brought up to date instead. The third goes
into that folder, and the fourth runs the install script. Capitals and the - matter.
If the fourth line says “No such file or directory”, open the
PoolWind-download folder in the File Manager instead, press F4
(Open Current Folder in Terminal) and type bash install.sh there.
It asks for your password once: the password you chose in Raspberry Pi Imager (section 2). Nothing shows on the screen while you type it, not even dots; type it and press Enter.
The install script:
PoolWind folder in your home folder. This is
where the program, its settings files and the CSV Vault live;It writes everything it does to a log file, install.log, in the
PoolWind folder. If something goes wrong, that’s the place to look.
It never overwrites settings or calibration files you already have, so it’s
safe to run again. When it updates the program, it keeps the previous one
as poolwind.py.previous.
When it finishes, restart the Pi.
When the screen comes back, there will be a “PoolWind” icon. PoolWind controls the pool from its first start: don’t start it until the hardware is connected and checked (build guide, section 9), and then as section 4 describes. To see PoolWind without a pool, try the demo on a Windows PC (section 13).
PoolWind controls the pool from its first start. Suggested before starting:
Double-click the PoolWind icon. The pool screen appears, showing the camera’s view from above, and a box winds the jet down to the swimmer’s slowest zone. If a box says the voltage sensor isn’t found, check the interface board (build guide, section 9). If it says the pump sensing line isn’t connected, fit R6 and R3 on the interface board (build guide, section 4).
Check that:
These settings fit PoolWind to your pool. They’re stored in
poolwind_calibration.txt, next to the program. Do them in this order,
which is also the order of PoolWind’s menu:
The calibration file is safety-critical. It decides which voltages PoolWind drives the jet to. Only someone who understands the system should change it.
This is a good time to talk about what these terms mean.
poolwind_calibration.txt
file on the SD card.
Swimmer datasets consist of their own Pace-volt calibration, swim data, and swim videos.
This tells PoolWind where the pool is in the camera’s picture.
A swim goes on while the swim area is set: the jet and the pump stay as they are, and the new corners count only once saved.
Do this again if the camera is ever moved.
The camera check. Saving the swim area also saves the camera’s
picture, as poolwind_calibration_camera.png next to the calibration file.
A few seconds after each start, PoolWind compares the camera’s picture with
it, looking only outside the water (deck, benches, jet unit). If the camera
has moved, it asks Camera moved? and offers:
Adjust moves the swim area’s four corners with the picture (sideways, up and down, a slight turn, nearer or farther) and saves them, so the next start uses them and doesn’t ask again.
If the camera has moved too far to follow (part of the pool out of the picture, or turned or tilted more than a little), or PoolWind can’t recognize the pool although the light is about the same, it says Check the camera instead: move the camera back so it sees the whole pool as before, then start PoolWind again, or press Set Swim Area.
Changing the swim area on purpose, for example for a jet box extension, saves a new picture, so the check never asks then. If the swim area’s length changed, change the usable swim length too (5.9). In the dark, when there isn’t enough to compare, the check says nothing.
On the pool screen, open the menu (≡, top left) and choose Calibrate pool….
This is an automatic scanning operation that must be run before any other calibration. This scan runs the jet from its slowest to its fastest speed, creating and building the Pace-volt table by filling in the measured voltages found.
In this PoolWind version, code only supports a pool with a feedback voltage range in discrete steps (like the author’s). A continuous voltage range will need programming changes. The link to ‘Claude’, made as an icon on the screen, will send a note describing PoolWind and the method needed to make a ‘continuous’ voltage range if necessary. This routine checks for stepped vs continuous and will give a warning message if the voltage range is not stepped before quitting. It is up to the builder to implement this.
At this point Pace is not yet filled in. Basically, the program operates with only the voltages, jet speed is determined by voltage and the swimmer position determines the voltages.
It is most important that the builder presses “Stop”, then “Use as top”, when they feel the jet speed is high enough and going further puts unnecessary strain and wear on the pool. PoolWind respects this decision and will never run the jet higher.
The Pace-volt table’s first and last rows become the jet’s limits. This procedure combined with Swimmer limits and programming establish the “feel” of the pool, how fast the swimmer swims in the highest zone, how slow in the lowest zone, and how it “feels” to transition through the zones. Pace settings have nothing to do with the “feel”.
poolwind_calibration.txt.
If re-initializing, the old Pace-volt table is kept in temp/poolwind_calibration_before_<date>.txt. The scan data is also kept as temp/calibration_scan_<date>.csv.The scan’s Paces are a first estimate. The scan measures only your pool’s voltages, not its speeds, so the associated Paces it writes are estimated: 7:00 at your pool’s slowest step, 1:00 at its top (where you pressed Stop, or the jet’s fastest speed), and in between, the shape of the author’s table. That’s realistic enough for PoolWind to run and to start swimming with. Pace Entry and PingPong replace the estimates with Paces measured on your pool, and Pace correction in PoolWind’s menu adjusts them to what feels right from your own swimming experience.
To scan again later if necessary, press Begin initial voltage scan again. It says the scan has already been run and asks Replace or Cancel. The scan starts over: any changes made to the Pace table are replaced by the first estimate above.
This routine is used if the pool has a Pace display. It’s recommended to use this over PingPong. It’s the best the manufacturer can give you for your pool. Afterwards, you can always edit the Pace values with Pace correction. Do not insert a USB stick since you are still setting up and building the Master dataset.
On the pool screen, open the menu (≡, top left) and choose Calibrate pool….
Pace here is only an estimate. It can never be exact due to the varying speed of layers as you go from top to bottom. It is different for stroke styles and body types depending on how deep you go (your legs mostly). But after calibration, it is close and consistent enough for training. You can only measure an accurate Pace in a regular pool.
Before you start
Edit screen This routine opens the edit screen first where it displays the current Pace-volt table. If you have not done a ‘Pace entry Auto scan’ before, skip edits and press the ‘Auto scan’ button (see below). You can select a row on the table and the jet speed will step to the row selected. It will pause a moment to let the pool settle and then allow you to re-enter the Pace showing on the Pace display. Enter the correct three digits - entering the third digit completes the edit. Rows showing —– are jet steps the initial scan found above the table’s top (the table was ended lower with Entry complete, below). They are not part of the table, but you can select one and enter its Pace: it then joins the table and raises the jet’s top to it.
Auto scan clears the table’s Paces, takes the jet down to its slowest speed, then steps it up one step at a time to the top the initial scan found (the —– rows too) while you type the Pace at each. There will be a pause at the start and between entries for the jet to settle. A Pace that can’t be right or mis-entered turns red and the scan goes on: there’s no time for corrections.
Once the top speed has been reached, the jet steps back down, stopping at each red step to ask again for the Pace display entry. Back stops the scan: displaying two buttons: Back (again) goes back and carries on and Continue keeps what you typed, takes the jet down and the Edit screen comes back. This occurs in about 30 steps, 10-20 minutes. If you did not finish the scan, the table will be interpolated for the final end points. If there are warnings, edit the entries as explained above.
Entry complete (after two steps are typed): when you have entered enough steps, or the pool shouldn’t go any faster. The last step you typed becomes the top of the table, the jet’s fastest speed. The steps above it show —– and are left out of the table, but kept: the next Pace Entry or PingPong shows them again. The jet goes down and the Finish screen comes up; nothing is saved until Save Table.
Finish (from the Edit screen): shows the new table beside the current one,
and how far apart they are in %. Steps without a Pace get a calculated
Pace, marked ~: interpolated between the steps typed, and extended on
to 1:00 at the fastest step and 7:00 at the slowest. A step that isn’t faster than the step below is marked red.
While the jet is still going down, Save Table and Quit are greyed out (“Taking the jet down…”).
Save Table replaces the Master table (it asks first, and warns if a step is still red) and goes back to PoolWind. Edit table goes back to the Edit screen.
Quit leaves without saving, after “Are you sure?”.
You would mainly use this if you are unhappy with the rough initial Pace values and do not have the Pace display. Afterwards you can always edit the Pace values with Pace correction. Do not insert a USB stick since you are still setting up and building the Master dataset.
On the pool screen, open the menu (≡, top left) and choose Calibrate pool…. This section and the previous one (5.4) deal with entering Pace.
Pace here is only an estimate. It can never be exact due to the varying speed of layers as you go from top to bottom. It is different for stroke styles and body types depending on how deep you go (your legs mostly). But after calibration, it is close and consistent enough for training. You can only measure an accurate Pace in a regular pool.
Before you start
You need five orange ping-pong balls (bright or fluorescent; white ones don’t work).
There is a starting line and a finish line drawn on the pool live video. When prompted, set one ball gently on the water right at the jet, in the middle. The measurement will begin when the ball crosses the starting line and end when the ball reaches the finish line. The distance is known from the pool calibration default of ‘usableSwimLength’. When 3 drops agree, it moves on to the next set while you are collecting the balls.
If you think enough balls have been dropped (in one set), you can press ‘Use dropped’. If you think the measurement was bad, you can press ‘Clear dropped’.
The ball rides on the surface which is the fastest level that the jet pushes. Lower levels move slower and the bottom is practically still. A swimmer typically occupies the top 10 inches, not counting hands and legs, and so would move slower than the pingpong balls. So the ball’s pace is turned into a swimming Pace with two numbers: bodyDrag, the factor at the jet’s fastest speed (1.50), and deltaBodyDrag, how much more it is at the slowest (0.18). Between the two, Pace changes evenly, step by step. These are defaults that work in the author’s pool, an educated guess. The results screen shows both: change them and the table follows. They’re kept in the calibration file with the ball measurements, so they can be changed again later in Pace correction.
During measurements:
When stopped either manually or at the jet’s top (the top the initial scan found; PingPong also goes on into the —– steps above the table’s top, see 5.4):
PingPong ends with a results table, new against current. Steps above your last ball set that are in the table show ... and are filled in when saved; the —– steps above the table’s top are left out unless you measured them. A step that isn’t faster than the step below is marked red.
Briefly:
The initial voltage scan (5.3) produces an accurate voltage scan but rough Pace values in the table. The swimmer can swim with the ‘feel’ of PoolWind but all calculations depending on Pace like distance and average Pace will probably be off. You can keep these values or, if not satisfied, use (2.) or (3.) below.
Pace entry (5.4) will use the manufacturer’s best guess of Pace as displayed on the Pace display. The Pace entries of the initial voltage scan will be replaced by hand entered values of what is displayed. This will be the better choice over PingPong if you own the Pace display.
Use PingPong if you have no Pace Display. PingPong (5.5) will accurately measure the surface speed of each of your pool’s ‘zones’ using the pingpong balls. But the actual Pace needs a drag factor and change of drag factor to multiply the pingpong measurements. Those factors are just guessed at. The routine gives a dynamic plot of how these factors affect Pace as well as being able to edit points. So with a little experience you may arrive at a pretty good table.
‘Pace correction’ offers a dynamic way to edit the Pace values that you feel are off and replace them with values based on your swimming experience. Even a single entry, say based on your fastest measured time in a real pool, will help and the surrounding Pace values will be interpolated. More entries, say based on other styles, will improve the Pace values even better yet.
If the builder thinks they can improve the calibration Pace values for the Master dataset, they would not plug in a USB stick while using Pace correction. Changes go to the Master dataset.
If a swimmer thinks they can improve the values of the Master dataset for themselves personally, they would have their USB stick plugged in. Changes go to the Swimmer dataset on the USB stick. While swimming, Swimmer dataset values override the Master dataset values.
Earlier swims change too.
A change in the Pace-volt table will change the Pace values when the swim is viewed in the Swim Plot… routine.
See Your earlier swims change too in the user manual’s Pace correction section.
See the user manual for more details on this routine.
There is no separate limits setting: the Pace table’s first and last rows are the jet’s limits.
The scan ends the table where you stopped it (Use as top), or at the jet’s top speed. Pace Entry and PingPong never step the jet above it. The limits always come from the pool’s table, never from a swimmer’s.
Before PoolWind v15.6 the limits were a 'SafetyVoltageLimits' line in the
calibration file. An old line is ignored now, and the next scan takes it
out.
Changes to the calibration file take effect at the next start.
Set both on the first screen of Calibrate pool (menu ≡, top left), under Pool settings, then press Save. There’s no need to open the calibration file.
PoolWind uses the new values as soon as the calibration window closes.
PoolWind keeps its settings in plain text files next to the program, all starting with the program’s name:
| File | Holds | Who changes it |
|---|---|---|
poolwind_defaults.txt |
The swimmer settings for anyone without a USB stick | The builder, and Swimmer limits with no stick in |
poolwind_calibration.txt |
The Master Pace table (the zones; its first and last rows are the jet’s limits), swim area, swim length, swim zone width, the scan’s results (InitialCalFinished, jetVoltageRange, jetStepVolts: every jet step the scan found, so Pace Entry and PingPong can show steps above the table’s top again, PacesFromFormula: the Paces are still the scan’s estimate), PingPong’s numbers (bodyDrag, deltaBodyDrag, PingPongBalls), Pace correction’s pending changes for swimmers without a stick (PacesPending), and the update’s logsTable / rulerAdded (section 10) |
The calibration, Pace correction and the builder |
poolwind_calibration_camera.png |
The camera picture the swim area was set on (the camera check, 5.2) | PoolWind, when the swim area is saved |
poolwind_ind_defaults.txt (on each USB stick) |
One swimmer’s own settings | Swimmer limits, and a new stick’s setup |
poolwind_ind_calibration.txt (on each USB stick) |
One swimmer’s own Pace table, their Pace correction’s pending changes and drag numbers. Made from the pool’s table the first time the stick is used | Pace correction |
poolwind_pump_log.txt |
How long the pump line took to follow each On/Off press, a line per press. Delete it any time | PoolWind |
temp folder (next to the program, and on each USB stick) |
Files PoolWind never needs to run: the backups made before a table is replaced (..._before_<date>.txt), the calibration’s records (calibration_scan_, calibration_session_, calibration_drops_, calibration_correction_<date>.csv) and developer traces. Delete it any time; PoolWind makes it again when needed |
PoolWind |
The swimmer settings use the same names in the defaults file and on the USB sticks. A stick’s value wins while it’s inserted. Swimmers set them with Swimmer limits in PoolWind’s menu (user manual, section 8):
| Setting | Example | Meaning |
|---|---|---|
'zoneMin, Max' |
(8, 22) |
Slowest and fastest zone (zone 1 is the jet’s slowest step) |
'swimmersHeight' |
66 |
Height in inches |
'recordTrainingVideo' |
True |
Record the training video for Swim Plot |
'logRate' |
5 |
Frames per second, swim log rows and video frames: 1 to 15 in the file, 5 to 15 in Swimmer limits (restart) |
'paceMin, Max' |
('5:00', '3:00') |
Older files only: a Pace range in place of zones, turned into zones by PoolWind. 'zoneMin, Max' wins if both are there; Swimmer limits replaces it |
On a stick they’re in poolwind_ind_defaults.txt, and the swimmer’s own
Pace table in poolwind_ind_calibration.txt, which only Pace correction
should change.
The defaults file as shipped uses a moderate range of zones, (6, 12)
(about 4:34 to 3:07 per 100 yards on the shipped Pace table), and an
average height. If you raise the fastest zone for yourself, remember it
applies to anyone who swims without their own stick.
Zones on the sticks. A swimmer’s stick holds their slowest and fastest
zone ('zoneMin, Max'), set with Swimmer limits. The defaults file uses
zones too. An older pace range ('paceMin, Max') still works: PoolWind
turns it into zones through the Pace table. Zone numbers belong to
the Pace table they were set on: after a new scan, set the swimmers’
limits again.
Recording rate ('logRate'). How many swim log records, and training
video frames, PoolWind saves per second: 1 to 15, read when PoolWind
starts. Swimmers set it (5 to 15) with Swimmer limits, on their stick or,
with no stick in, in the defaults file for everyone (a coach’s choice, for
example).
'logRate' |
Video | Storage | A 32 GB stick holds |
|---|---|---|---|
5 (shipped) |
Steps visibly between frames; enough to follow pace and stroke rhythm | About 7 MB a minute | About 70 hours |
15 |
Smooth stroke detail, even slowed down | About 20 MB a minute | About 25 hours |
Higher rates also use more of the Pi’s time (about 10 % at 15), so 15 is the limit.
Ejecting the stick at close. When PoolWind closes, it always writes
everything to the swimmer’s USB stick and unmounts it, so it’s safe to
remove. There’s no message, except when something else was using the
stick and it couldn’t be ejected. The stick isn’t powered off, so if it
stays in, the next start mounts it again. To see its files in the File
Manager after PoolWind closes, unplug it and plug it back in. (The
'ejectStickOnClose' setting is gone since v15.7; a line left in a file
is ignored.)
The files are written like this:
{
'swimmersHeight': 66
,'zoneMin, Max': (6, 12)
}
True and False have capital letters.# are comments, ignored by PoolWind.If the defaults or calibration file can’t be read when PoolWind starts, or
the defaults file has a misspelled setting name or a wrong word (such as
'poolx'), PoolWind doesn’t start: a box shows the file, the line and the
problem. Fix it, save, and start PoolWind again. If you make a mistake while
it’s running, it says so in the terminal and keeps the last good settings.
PoolWind only ever changes single lines in the defaults file (Swimmer limits without a stick, Set Swim Area in video mode), so your comments stay.
These were tuned during development and are built into the program. To
change one, add its line to poolwind_defaults.txt, with exactly the same
name. The file’s value then replaces the built-in one. Delete the line to
go back.
Most take effect while PoolWind is running. Those marked restart need PoolWind to be closed and started again.
| Setting | Built-in value | What it does |
|---|---|---|
'Demo' |
False on the Pi, True on a PC |
Developer: True runs the demo, the sample video with a simulated jet: nothing at the pool moves (restart) |
'Sensitivity' |
5000 |
Minimum size, in pixels, of something the camera counts as a swimmer |
'CoM filter Alpha' |
0.05 |
Smoothing of the swimmer’s position. Smaller is smoother but slower to react |
'inactivity wind down time (sec)' |
3 |
How long the swimmer may be out of the lane before the jet winds down (restart) |
'stillSeconds' |
15 |
Seconds without movement before a swimmer in the lane counts as gone (someone standing or floating) |
'stillMotion' |
0.25 |
How much of the swimmer’s shape must change to count as movement for 'stillSeconds' |
'autoSuspendMinutes' |
3 |
Minutes after that before PoolWind suspends the swim by itself. 0 never does |
'DRIFT_SCALE', 'DRIFT_TAU', 'DRIFT_MAX' |
1.67, 5.0, 25.0 |
The Swimmer Pace estimate. Leave these alone unless you’re developing |
'WATER_TAU' |
5.0 |
Seconds the water takes to catch up after the jet changes speed, for the Swimmer Pace estimate. (The zone highlight follows the jet directly.) |
'zoneHighlight' |
False |
Whether the zone highlight is on when PoolWind starts. A tap on the picture turns it on or off either way |
'zoneHighlightLevel' |
0.2 |
How bright the zone highlight is: 0.05 is barely seen, 0.3 is strong |
'developerMode' |
False |
Developer tools: see Testing at a desk. Also shows the position bar and the dIdx, V (jet voltage) and CoM readouts on the pool screen, shows the position bar on the Swim Plot video while the zone highlight is on, allows raw video, and opens Calibrate pool… with a USB stick in, without the builder’s password and whatever the workplace, valve or camera setting (Pace correction too; with the simulated valve the calibration uses the pool’s relays, sensor and camera itself). Users leave it off: the position bar also moves with swim angle and depth, not just the stroke, which would confuse a swimmer |
'readouts' |
True |
Developer: with developerMode on, False hides the dIdx, V and CoM numbers on the pool screen (for example for a screenshot) |
'comBar' |
True |
Developer: with developerMode on, False hides the position bar (pool screen and Swim Plot) but keeps the readouts. The zone highlight is the steadier reference |
'algorithm (basic or swimmerPace)' |
'swimmerPace' |
Developer: the control method. 'swimmerPace' is the method the manuals describe; leave it. 'basic' is a simple baseline for building new control methods on. Main defaults file only: a USB stick’s line is ignored |
'paceTrace' |
False |
Developer: writes a detailed temp/pace_trace_*.csv file of the pace estimate, about 15 MB an hour |
'recordRawVideo' |
False |
Developer: with developerMode on, records the camera’s full, uncorrected video, a tool for developing the swimmer detection. The files are large (restart) |
'Runtime: hotReloadParameters' |
True |
Picks up settings changes while running |
The swimmer settings also have built-in fallbacks, used only if the
defaults file leaves them out: every zone of the Pace table
('zoneMin, Max': None) and 'logRate': 5.
The swim log (CSV Vault/<date>.csv, one line per record, no header):
time, pace, distance, video segment, frame, position (CoM_h), swimmer
tick (CoM_w, -1 = none), and since the zone highlight, the jet’s zone
(-1 = none) and the number of zones. Older files without those columns
replay without the highlight. Since v15.7 two more: the jet’s voltage and
the Pace the table in use gave there, so Swim Plot can show any swim in
today’s table (user manual, Swim Plot). Logs from before
v15.7 are given these two columns once after the update
(section 10).
These developer settings let you run PoolWind without the pool. They only
work with 'developerMode': True in poolwind_defaults.txt (and no
'Demo': True line): with developerMode off PoolWind always runs the
real pool setup, whatever the file says. Add them to poolwind_defaults.txt;
they all need a restart.
| Setting | Normal | Meaning |
|---|---|---|
'Valve (real or simulate)' |
'real' |
'simulate' runs without pressing the remote’s buttons |
'capture_device (camera or video)' |
'camera' |
'video' plays a recorded swim instead of the live camera |
'display_device (work or pool)' |
'pool' |
'work' switches the monitor to landscape for programming, and 'pool' back to portrait (monitor mode set in the program code) |
'workplace (home or pool or default)' |
'pool' |
Sets all three above at once: 'home' = video, work, simulate; 'pool' = camera, pool, real; 'default' = use the three lines as written |
'video file, start (sec), corners' |
'PoolWind_demo.mp4', 0, the sample’s corners |
The recorded swim 'video' (and the demo) plays: its file, the number of seconds in to start, and the swim area’s four corners in that video |
To add them, copy these lines into poolwind_defaults.txt, just before
the closing }. They’re set for pool use, so nothing changes until you
change a value: for a desk test, change 'pool' on the workplace line to
'home'.
,'developerMode': True
,'workplace (home or pool or default)': 'pool'
,'capture_device (camera or video)': 'camera'
,'display_device (work or pool)': 'pool'
,'Valve (real or simulate)': 'real'
,'video file, start (sec), corners': ('PoolWind_demo.mp4', 0, [(153, 148), (479, 151), (384, 601), (184, 583)])
The pump relay is only connected when the workplace is 'pool'. So
'default' with 'Valve (real or simulate)': 'real' tests the speed
relays at a desk with no chance of starting the pool’s pump. OnOff then
presses nothing, and its button still shows the pool’s pump. With the
simulated valve the pump is simulated too: OnOff turns it on and off.
The last line is the built-in value, for the sample video. To use your own
recording, add the line to poolwind_defaults.txt with its file name
(next to the program, or a full path), the seconds in to start, and corners. For its corners, run it and use Set Swim Area: in video mode,
the corners are saved in this line of poolwind_defaults.txt, and the
pool’s own swim area in the calibration file is left as it is. If the file
isn’t found, PoolWind says so and uses the camera.
Before swimming, delete these lines or set 'developerMode': False.
With 'work', PoolWind’s window keeps its title bar. While Swim Plot is
open it says Using Swimmer Pace-Volt or Using Master Pace-Volt, and its
× closes Swim Plot, not PoolWind.
The calibration has no simulation: it always drives the real jet. With
the simulated valve, Calibrate pool… uses the pool’s relays, voltage
sensor and camera itself (with 'developerMode': True, which these settings
need, it and Pace correction… stay in the menu). Its screens open with the pump off, and a
tapped Pace Entry row still drives the jet’s valve, which moves with the pump off too; Start
needs the pump running and offers to turn it on.
You can work on the Pi from a computer elsewhere in the house while it stays at the pool: change settings, look at swim logs, or work on the program.
Connecting:
poolwind.local (the
hostname you chose in section 2), or by its network address. Your
computer and the Pi must be on the same home network.The Monitor Toggle icon. In portrait, the pool monitor’s picture is too narrow to work in comfortably, and VNC shows you the same picture. Double-click Monitor Toggle on the Pi’s desktop to turn the monitor to landscape (full width) while you work. Double-click it again to turn it back to portrait. Restarting the Pi also turns it back to portrait.
Always turn the monitor back to portrait before anyone swims.
Another monitor. The toggle is set up for the author’s monitor (the
Eyoyo 10-inch on the parts list): portrait at 800×600, landscape at
1280×800, on the output called HDMI-1. Another monitor usually works
without changes: if HDMI-1 has no monitor, the toggle uses whichever
monitor is connected, and if the monitor doesn’t offer one of those sizes,
it uses the monitor’s own preferred size. PoolWind adapts its screen to
whatever size it finds.
To choose the sizes yourself, open ~/.local/bin/toggle_monitor.sh in a
text editor and change the three settings at its top. To see your
monitor’s output name and the sizes it offers, type xrandr in a
terminal. Updating PoolWind keeps these settings.
PoolWind tells you when there’s a new version. When it starts with an internet connection, it checks whether a newer version has been published and, when nobody is swimming, shows what’s new with two buttons:
To update by hand, download the new version and run the install script again:
cd PoolWind-download
git pull
bash install.sh
(In a new terminal, which starts in your home folder; copy and paste the
lines the same way as in section 3.) The four lines of section 3 also
update, whether or not the PoolWind-download folder is still there: it’s
the same script.
The same script installs and updates. On an update it replaces the program
(keeping the old one as poolwind.py.previous) and leaves everything else
as it is: your settings, your pool’s calibration, swim logs, videos and USB
sticks. When it finishes it says which version it updated from and to, and
what’s new.
Updating to v15.8 or later needs R6 and R3 fitted on the interface board (build guide, section 4): PoolWind uses them to see whether the pump is running, and doesn’t start without them. Updating from an earlier version, the install script asks first, and changes nothing if they aren’t fitted.
The new version reads the older files as they are. Updating from v15.5 to v15.7 or later, for example:
'SafetyVoltageLimits' line is ignored (the jet’s
limits are the Pace table’s ends, 5.8);'logsTable' in the
calibration file: the table the old swims were swum with;CSV Vault, the Pi’s and each USB stick’s, when
the stick is first used) has its old logs given the jet’s voltage and
Pace once, so Swim Plot can show them in today’s Paces; it’s marked
'rulerAdded', and takes a few seconds;The install script can rebuild the software at any time. What it can’t rebuild is yours, so back it up:
poolwind_calibration.txt: your pool’s measurements;poolwind_defaults.txt: your settings;CSV Vault folder next to the program, for swimmers without a stick;Copy them to a PC or another USB stick now and then, and always before changing the SD card.
PoolWind has no support, but you’re not on your own:
PoolWind-download folder (section 3).Claude Code is Anthropic’s AI assistant for working with programs. It runs in a terminal on the Pi, where it can see PoolWind’s files. It needs a paid Claude account.
The download includes CLAUDE.md, a detailed description of PoolWind
written for Claude: how the program works, the hardware, the safety rules
and known problems. Claude Code reads it by itself whenever it starts in
the PoolWind-download folder, so there’s nothing to copy or paste. It can
read PoolWind’s messages with you, explain settings, and help change the
program for a pool or camera that differs from the author’s, such as a
pool whose speed voltage drops to zero while the pump is off. Test any
change with nobody in the pool first.
The easy way: the Claude icon on the Pi’s desktop, which the install script adds. Double-click it:
PoolWind-download folder,
carrying on your last conversation. Claude has read CLAUDE.md as it
starts.Claude runs in a shared session (tmux): the Claude icon on the Pi and the
same command from a PC (below) show the same Claude, so you can go from
one to the other in the middle of a conversation. Closing the window
leaves Claude running for next time; /exit in Claude ends it.
The install script sets up the web browser so it doesn’t ask for a “Default keyring” password when it saves the sign-in. If it asks anyway (on a Pi set up before November 2026), leave both fields blank and click Continue, and it won’t ask again.
By hand (for example over SSH from a PC, below):
curl -fsSL https://claude.ai/install.sh | bash
echo 'export PATH="$HOME/.local/bin:$PATH"' >> ~/.bashrc
source ~/.bashrc
The second and third lines let the terminal find claude. If the
installer prints a note about PATH, ignore it: those two lines do it.
cd PoolWind-download
claude
The first time, it asks you to sign in: it shows a link to open in a web browser.
Either way, once you’re signed in:
Describe the problem in your own words. Claude Code has already
read CLAUDE.md as it started, so it knows PoolWind’s background. For
example: “the jet doesn’t move when I press UP” or “my pool reads zero
volts when it’s off”. It asks before reading files outside the folder (such as the
installed PoolWind folder) or running anything.
To check that it has the background, type /memory: it lists the
CLAUDE.md files it has loaded, and PoolWind-download/CLAUDE.md should
be among them. If it isn’t, Claude Code was started in another folder:
type /exit, then start it again with step 2.
To go back to your last conversation later, start it with claude -c
instead of claude. To finish, type /exit.
The author talks to Claude from a PC in the house, in its own window, while the Pi stays at the pool. The PC needs nothing more than the Pi already has: Claude runs on the Pi, and the PC only shows its terminal.
ssh yourname@poolwind.local
The first time, answer yes to the question about the Pi’s key, then type the Pi’s password. The window is now a terminal on the Pi.
.local/bin/poolwind_claude.sh
Or all in one line from the PC, steps 3 and 4 together:
ssh -t yourname@poolwind.local .local/bin/poolwind_claude.sh
At the pool, double-click the Claude icon on the Pi: it shows the same Claude as the PC, mid-conversation if you were in one. Closing the PC’s window leaves Claude running on the Pi. When the Pi is switched off, Claude stops, but the conversation is kept: the next start carries on with it.
You can try PoolWind on a Windows PC before building anything. It runs as a demo: a recorded swim plays on the pool screen, and the jet is simulated, so you can see how PoolWind follows a swimmer, how the zones and the Pace work, and try Swim Plot. A PC can’t control a pool: that needs the Raspberry Pi build.
You need: Windows 10 or 11, an internet connection, and about 1 GB of free space (most of it for Python and its libraries).
install_windows.bat.install_windows.bat (in your
Downloads folder).PoolWind folder in your
user folder. The video is a hidden file. When you close PoolWind,
the whole PoolWind folder is deleted.Everything it does is written to install.log in that folder.
Click Download the PoolWind demo again and run it. The script deletes itself from Downloads when it finishes, so copies don’t pile up there. Python and the libraries are already there, so it only downloads the sample video again, then the tour opens and the demo starts. It also brings you the latest PoolWind.
Why the warnings? Windows and the browsers warn about any program or script from the internet that isn’t signed by a known publisher, and PoolWind is a hobby project without one. The script is plain text: to see what it does before running it, right-click it and choose Edit (or Open with → Notepad).
Closing PoolWind already deletes its PoolWind folder (if PoolWind was
stopped some other way, delete that folder in your user folder yourself).
If the script installed Python and you don’t need it, remove
Python 3.13 in Settings → Apps.